Long line heating cable (SCW SERIES)
Structure

Application range
Series resistance heating system mainly used to prevent freezing and maintain system temperature
It is used in hazardous areas and places exposed to corrosion and has the advantages of high operational
effectiveness, low installation price, and long lifespan.
Able to withstand exposure temperatures up to 250℃ and be used as a long-distance system
(Tunnel internal fire extinguishing equipment, crude oil transfer line)
Able to be installed in various areas(including explosion-proof and non-explosion-proof)
Technical specifications
Range of operating temperature : -40℃ ~250℃
Length of use : Max. 5km
Applied voltage : Max. 750V
Rated output : Max. 50W/m (Heating capacity can be arbitrarily adjusted by changing the resistance of
the conductor and supply voltage)
Minimum bending radius : 6 × Cable external diameter
International standards : UL (AWM 10142 Style), ATEX (KRH 14 ATEX 1018U), EAC
Product code selection
| scw | F | V | S | V | 3C | 1.50 |
▲ Model | ▲ 1st insulation | ▲ 2st insulation | ▲ Shielding braiding | ▲ Sheath | ▲ Cable structure | ▲ Conductor specifications |
System configuration

Comparison of output according to voltage and len

Detailed specifications
| Model | Conductor | 1st insulation | 2nd insulation | Sheath | Test voltage (V/5min) | ||
| External diameter (㎜?) | Conductor resistance (Ω/m) | Thickness (㎜) | Thickness (㎜) | Thickness (㎜) | Completed external diameter (㎜?) | ||
| SCW-FVSV-3C1.5 | 1.61 | 11.6 | 0.55 | 1.20 | 1.50 | 8.90 × 16.70 | 1600 |
| SCW- FVSV-3C2.0 | 1.82 | 9.0 | 0.55 | 1.20 | 1.50 | 9.10 × 17.30 | 1600 |
| SCW-FVSV-3C4.0 | 2.99 | 4.4 | 0.55 | 1.20 | 1.50 | 10.30 × 20.90 | 1600 |
| SCW-FVSV-3C6.0 | 3.60 | 3.0 | 0.70 | 1.20 | 1.50 | 11.20 × 23.60 | 1600 |
| SCW- FVSV-3C10.0 | 4.68 | 1.8 | 0.70 | 1.20 | 1.50 | 0 12.30 × 26.90 | 1600 |
The table above shows the basic model, and other specifications can be designed and manufactured separately.