Fluorine-insulated constant wattage heating cable (YFH SERIES)
Structure

Application range
Parallel structure provides constant first designed unit power regardless of length or ambient temperature
Industrial pipeline system, prevention of freezing of tanks
Places where high temperature environments and chemical resistance are required, such as industrial plants
Technical specifications
Range of operating temperature : -90℃ ~250℃
Applied voltage : 110V or 220V (The applied voltage can be designed to change upon customer request)
Design capacity : 50W/m (40W/m ~60W/m)
Bus wire : 3.0sqmm
Surface temperature by output level (Based on room temperature 20℃)
| Unit output | Based on room temperature 20℃ | Ambient temperature 5℃/strong> | ||||
| 40W/m | 50W/m | 60W/m | 40W/m | 50W/m | 60W/m | |
| Surface temperature | 80℃ | 100℃ | 110℃ | 50℃ | 70℃ | 85℃ |
* Since it is not a self-control method, a separate controller sensor device is required because the temperature rise may vary depending on the insulation treatment.
Maximum usage length (based on 90% output)
| Unit output | 40W/m | 50W/m | 60W/m |
| Maximum usage length | 72m | 65m | 59m |
Product model classification
| Model | Structure | Size | Design |
| YFH-201 | Basic type | 6.40/9.50 |
|
| YFH-202 | Basic type + Exterior braiding (SUS 304) | 6.90/10.00 |
|
| YFH-203 | Basic type + Shielding braiding + External sheath (Fluororesin) | 7.90/11.00 |
|